Sounds like the controller output isn't correct for the relay. When I went to the Bartlett for my one annealer I had to change the relay as the input was different. I am still in my first year with the bartletts.

1) Love the number of programs.
2) Love how easy they are to program.
3) It is great having the phone app to check the annealer.
4) It is handy to be able to download the 30 second by 30 second view of actual and target temps.
5) Wish they ramped a bit faster when you open the door.
6) Wish they had an honest soak step.
7) They program by rate and temp not time. Would be nice to have a time and target option.