It's been on my list to look into for years, but I'd finally like to try to get something up an running that would perform a similar function to what I've heard called "auto dialers" which call your phone number if your safety system shuts off the flame to a gas furnace. But my issue is that I don't have a phone line over at my shop. I do, however, have fairly reliable DSL wi-fi there. So could anyone make a recommendation for some device that might be out there that could be utilized to send me a phone call or text message via the interwebs? I was talking to someone at Instrumart recently (my Watlow distributor) and they seem to know of a solution but it's fairly expensive and way more features than I need for just this basic power signal interruption notification. Thanks in advance.
__________________
www.jmbglass.com
instagram.com/joshbernbaum_glass
Reply With Quote
  #2  
Old 05-28-2020, 10:25 PM
Eben Horton Eben Horton is offline
Registered User
 
Join Date: Apr 2002
Location: Wakefield, RI
Posts: 4,716
Eben Horton is on a distinguished road
Proteus C5 - WiFi Electric Load Sensor with email/Text alerts https://www.amazon.com/dp/B07G7HQWLX..._5ai0EbETHACEV
__________________
<eben epoiese>
Reply With Quote
  #3  
Old 05-29-2020, 04:14 AM
John Riepma John Riepma is online now
Registered User
 
Join Date: Apr 2003
Location: Grand Haven, MI
Posts: 518
John Riepma is on a distinguished road
This is what I use for power outage/restoration alerts.
https://www.pumpalarm.com/
Reply With Quote
  #4  
Old 05-29-2020, 07:27 AM
Josh Bernbaum Josh Bernbaum is offline
Registered User
 
Join Date: Feb 2009
Location: Brattleboro, VT
Posts: 679
Josh Bernbaum is on a distinguished road
Thanks, you guys are awesome!
__________________
www.jmbglass.com
instagram.com/joshbernbaum_glass
Reply With Quote
  #5  
Old 05-29-2020, 08:44 AM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
The other thing to consider is a webcam like a dlink pointed at your control panel. I have a cloud backed dlink in my shop pointed at my controller. My problem isn't so much power outages as surges and partial drops. They don't trigger my power outage alarm but do trigger the furnace safety mechanisms. What I lucked out on is that my cheap century link router resets after power surges and drops. Because my router drops out the cloud loses connection with the camera and notifies me, I then just wait about 2 minutes and then check the control panel to see if we shut down. Has saved me the drive in to town in the middle of the night many times.
Reply With Quote
  #6  
Old 05-29-2020, 08:46 AM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
The dlink also helped me figure out why my motion detectors were getting set off in the middle of the night. Alarm went off and I scanned the hot shop, because it was dark the camera was in IR mode. Saw this fluttering hot spot flying around the shop. It was a bat flying around the shop.
Reply With Quote
  #7  
Old 05-30-2020, 06:28 AM
Josh Bernbaum Josh Bernbaum is offline
Registered User
 
Join Date: Feb 2009
Location: Brattleboro, VT
Posts: 679
Josh Bernbaum is on a distinguished road
Thanks Art, I do have a wifi cam pointed at both of my furnace controllers, which are super handy and I wouldn't want to run without them now, but they don't give me the alerts when needed. My backwoods DSL is occasionally spotty, and even though I get notifications that the camera is off when there's an issue, it mostly isn't the case for me that my safety system has tripped when that happens, usually just an interruption in the internet signal.
__________________
www.jmbglass.com
instagram.com/joshbernbaum_glass
Reply With Quote
  #8  
Old 05-30-2020, 11:51 AM
Pete VanderLaan's Avatar
Pete VanderLaan Pete VanderLaan is offline
The Old Gaffer
 
Join Date: Apr 2002
Location: Chocorua New Hampshire
Posts: 21,958
Pete VanderLaan is on a distinguished road
It struck me a long time ago that a foolproof safety system restart would involve two burners. The first is presumably on a blower gas line combo which runs normally when the power is on and has a solenoid valve which is open when the power is supplied to it.

There would be a second burner which would be venturi and would be controlled by a normally closed solenoid that would only open if the power failed. It would be a fairly small venturi but sufficient enough in size to keep the furnace hot in a failure for a long time. It would fundamentally take the place of the "Crash Cart" burner a number of people use.

The only thing more reliable that I can see is using a Venturi with a BASO valve but Venturis are typically more expensive to run continuously . I run a variant of this described setup now and it takes a power failure longer than one hour to make the system shut down. When it shuts down, it turns the whole mess off. It does not shut down in an intermittent power outage. It just restarts.
__________________
Where are we going and why am I in this basket?
Reply With Quote
  #9  
Old 05-31-2020, 12:14 AM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
My challenge with something like that would be that my exhaust blowers wouldn't be running.
Reply With Quote
  #10  
Old 05-31-2020, 06:52 AM
Pete VanderLaan's Avatar
Pete VanderLaan Pete VanderLaan is offline
The Old Gaffer
 
Join Date: Apr 2002
Location: Chocorua New Hampshire
Posts: 21,958
Pete VanderLaan is on a distinguished road
That would be unlikely in a fairly short term shutdown. The venturi doesn't generate much in the way of combustion gas.

Sometimes nothing you do will help. The worst power failure we ever had was in our overhead fluorine melter. It was an AZS 200lb unit and we had just put about a forty lb charge in it of a cadmium yellow opaque and someone hit a power pole knocking it down. The vents failed and they were big vents running 30,000 CFM from the building. The black smoke began to billow out of the furnace and we evacuated the shop entirely. The failure went on for four hours. They furnace was essentially destroyed throwing stones the size of a clamshell. Never ran it again.
__________________
Where are we going and why am I in this basket?
Reply With Quote
  #11  
Old 05-31-2020, 01:02 PM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
Yep, snowmegeddon killed us last year. Since there were no residences in our chunk of the grid we were brought up last. We kept the glass a bit soft with a fluffy but the CO started to build up because we had no exhaust and the electric louvers shut when they lose power.
Reply With Quote
  #12  
Old 06-04-2020, 11:57 AM
Foster Holcombe Foster Holcombe is offline
Registered User
 
Join Date: Sep 2009
Location: Laytonsville, MD
Posts: 9
Foster Holcombe is on a distinguished road
auto dialer

We have used this one for the past 25 years with great success. Never needed replacement but have a couple backups. Cant beat how easy it is to set up and can be hooked to furnace or just power. Hope it helps
https://www.ebay.com/itm/RadioShack-...wAAOSw0o9eypap
Reply With Quote
  #13  
Old 06-05-2020, 10:04 AM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
What I really need is something that tells me if the power gets strange, my alarm system tells me when I lose power altogether but doesn't tell me when the power gets strange. I get more burner shutdowns from the power strangeness than power outage. Right now my cheap century link router serves that function but if they ever replace it with a better one I am kind of hosed.
Reply With Quote
  #14  
Old 06-05-2020, 10:09 AM
Mark Rosenbaum's Avatar
Mark Rosenbaum Mark Rosenbaum is offline
Registered User
 
Join Date: Apr 2002
Location: New Orleans, LA
Posts: 1,068
Mark Rosenbaum is on a distinguished road
I have my furnace alarm tied into my building alarm. If my furnace drops to 1850, I get a call....
Reply With Quote
  #15  
Old 06-05-2020, 03:29 PM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
Quote:
Originally Posted by Mark Rosenbaum View Post
I have my furnace alarm tied into my building alarm. If my furnace drops to 1850, I get a call....
What kind of controller and who designed your control panel? I would love to do that with mine.
Reply With Quote
  #16  
Old 06-06-2020, 02:53 PM
Mark Rosenbaum's Avatar
Mark Rosenbaum Mark Rosenbaum is offline
Registered User
 
Join Date: Apr 2002
Location: New Orleans, LA
Posts: 1,068
Mark Rosenbaum is on a distinguished road
Quote:
Originally Posted by Art Freas View Post
What kind of controller and who designed your control panel? I would love to do that with mine.
I will have to check with Sonitrol to see.... it is hooked up to my panel for my #400 Stadelman furnace
Reply With Quote
  #17  
Old 06-07-2020, 02:02 PM
Pete VanderLaan's Avatar
Pete VanderLaan Pete VanderLaan is offline
The Old Gaffer
 
Join Date: Apr 2002
Location: Chocorua New Hampshire
Posts: 21,958
Pete VanderLaan is on a distinguished road
Quote:
Originally Posted by Mark Rosenbaum View Post
I have my furnace alarm tied into my building alarm. If my furnace drops to 1850, I get a call....
****
So, if the building drops below 1850 , does the fire department get to go home?
__________________
Where are we going and why am I in this basket?
Reply With Quote
  #18  
Old 06-07-2020, 02:15 PM
Mark Rosenbaum's Avatar
Mark Rosenbaum Mark Rosenbaum is offline
Registered User
 
Join Date: Apr 2002
Location: New Orleans, LA
Posts: 1,068
Mark Rosenbaum is on a distinguished road
Quote:
Originally Posted by Pete VanderLaan View Post
****
So, if the building drops below 1850 , does the fire department get to go home?
Fire Department humor......
Reply With Quote
  #19  
Old 06-07-2020, 07:07 PM
Peter Bowles Peter Bowles is offline
Registered User
 
Join Date: Sep 2002
Location: Breadalbane, Tasmania
Posts: 636
Peter Bowles is on a distinguished road
Quote:
Originally Posted by Mark Rosenbaum View Post
I have my furnace alarm tied into my building alarm. If my furnace drops to 1850, I get a call....
I used to have the same. I had a dedicated setpoint controller and used the under temp and over temp alarms connected to the building security alarm.
Reply With Quote
  #20  
Old 06-08-2020, 03:16 PM
Art Freas Art Freas is offline
Registered User
 
Join Date: Aug 2014
Location: Washington
Posts: 642
Art Freas is on a distinguished road
Quote:
Originally Posted by Pete VanderLaan View Post
****
So, if the building drops below 1850 , does the fire department get to go home?
Only if they save the basement.
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -5. The time now is 07:32 PM.


All published comments within these message boards are the opinions of its contributor and does not represent
the opinion(s) of the owner(s) of this website. Please see the Terms of Use file for more details.

Books to Help Artists Avoid Online Scams: Top 10 Email Scams | Social Media Scams

Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2020, Jelsoft Enterprises Ltd.
CraftWEB.com. Opportunity Network. 2008. All Rights Reserved.